Huawei Smart SUN2000-600W-P Optimizer – General data
Dimensions (W × H × D): 71 × 138 × 25 mm (2.8 × 5.4 × 1.0 in.)
Weight (including cables): 0.55 kg
Installation accessories (optional): grounding plate, grounding clamp, PV module frame plate
Input connector: Staubli MC4
Output connector: Staubli MC4
Output cable length⁴*: 1.2 m
Operating temperature⁵*: -40 ~ +85 ℃
Humidity range: 0% RH ~ 100% RH
Protection class: IP68
Huawei Smart SUN2000-600W-P Optimizer – Input
Rated input power¹*: 600 W
Absolute maximum input voltage: 80 V
MPPT operating voltage range: 10 – 80 V
Max. input current: 14.5 A
Max. efficiency: 99.5%
Weighted efficiency: 99.0%
Overvoltage category: II
Huawei Smart SUN2000-600W-P Optimizer – Output
Max. output voltage: 80 V
Max. output current: 15 A
Output bypass²*: Yes
Output voltage shutdown per optimizer³*: 0 V
Output impedance at shutdown per optimizer: 1 kΩ ± 10%
Design (Full Optimizer)
SUN2000-2-6-KTL-L1: 4 – 25 | 6,000 W
SUN2000-3-10KTL-M1: 6 – 35 | 10,000 W
SUN2000-12-20KTL-M2: 6 – 35 | 12,000 W
SUN2000-30-40 KTL-M3: 6 – 25 | 12,000 W
Huawei Smart SUN2000-600W-P Optimizer – Communication protocol
Communication protocol: MBUS
Huawei Smart SUN2000-600W-P Optimizer – Standards compliance
Safety: IEC 62109-1 (Safety Class II)
RoHS: Yes
Huawei Smart SUN2000-600W-P Optimizer – Inverter compatibility
SUN2000-2 / 3 / 3.68 / 4 / 4.6 / 5 / 6 KTL-L1
SUN2000-3 / 4 / 5 / 6 / 8 / 10 KTL-M1
SUN2000-12 / 15 / 17 / 20 KTL-M2
SUN2000-30 / 36 / 40 KTL-M3
Huawei Smart SUN2000-600W-P Optimizer – Notes and explanations
1* In the STC environment, the rated power of the module must not exceed 1.05 times the optimizer’s rated input power.
2* The power optimizer is bypassed in a string connected to an operating inverter when it is not working.
3* OVdc output of the power optimizer when the inverter connection is disconnected or the inverter is switched off.
4* Enables installation of PV modules on framed / mounting / extruded aluminum profiles.
5* Suitable for PV module installation in landscape and portrait orientation.
6* Requires standard 60-cell modules to meet the inverter minimum start-up voltage.
7* Full performance refers to the intelligent online design tool.